Skip to content
Fault code dictionary (DTC)

P0A98 — Battery cooling fan 2 stuck on

Severity: Warning Can you drive? With caution: limp mode possible, have it checked soon Make: All makes (OBD-II standard)
MeaningThe control unit has detected that battery cooling fan 2 stays on even when it has not been requested. The fan runs, so cooling is not missing, but the command or its monitoring is not behaving as intended. It is not an immediately dangerous fault, but it needs to be clarified.
FamilyPowertrain (P)

Typical symptoms

Battery fan heard running constantly
Blowing noise from the rear seat area
Hybrid system warning light on
Fan staying on with the car switched off
Faster discharge of the 12-volt battery
No other obvious driving symptoms

Common causes

Fan relay stuck in the closed position
A short circuit in the control wiring
A fault in the control unit or module driving the fan
Battery temperature sensor giving wrong values and calling for constant cooling
Battery temperature really high because of another problem
A control software error

What to do

Check whether the fan stays on even with a cold battery and the car off: if so, the command is stuck. Have the system checked at a workshop within a reasonable time, because a fan that is always on uses energy and can drain the 12-volt battery. If the noise comes with temperature warnings, the priority goes up.

How to read code P0A98

This is a warning: the vehicle usually keeps working, but the control unit may limit performance (limp mode) until the fault is removed.

The code P0A98 starts with P: it belongs to the powertrain (engine and transmission) area. It is defined by the SAE/ISO standard, so it means the same on every make. The third character (A) points to hybrid propulsion, and the last two (98) identify the specific fault inside that group.

How to proceed, in order

  1. Read the code with the diagnostic tool and note the freeze-frame data and any other stored codes.
  2. Check connectors, wiring and grounds of the component involved, and the battery voltage.
  3. Measure the real values of the component with the diagnostic tool instead of replacing it by guesswork.
  4. After the repair, clear the code and confirm with a road test that it does not come back.

Frequently asked questions

What does code P0A98 mean?

Battery cooling fan 2 stuck on. The control unit has detected that battery cooling fan 2 stays on even when it has not been requested. The fan runs, so cooling is not missing, but the command or its monitoring is not behaving as intended. It is not an immediately dangerous fault, but it needs to be clarified.

Can I keep driving with code P0A98 active?

With caution: limp mode possible, have it checked soon

Common causes — P0A98

Fan relay stuck in the closed position A short circuit in the control wiring A fault in the control unit or module driving the fan Battery temperature sensor giving wrong values and calling for constant cooling Battery temperature really high because of another problem A control software error

How do you fix code P0A98?

Check whether the fan stays on even with a cold battery and the car off: if so, the command is stuck. Have the system checked at a workshop within a reasonable time, because a fan that is always on uses energy and can drain the 12-volt battery. If the noise comes with temperature warnings, the priority goes up.